Quartet FrontSolitaire FrontTOPAZDIRECT VENT ROOM HEATER Owner’s ManualInstallation and OperationModel: 839-1290839-1320839-1340844-4120TOPAZ-D-CSBR O
10 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/115Vent InformationA. Venting ComponentsB. Use of ElbowsIn order to comply with applicable codes a
11Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11D. How to Use the Vent Graph E. Venting Guidelines1. Measure the vertical distance from the cen
12 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Female Locking LugsMale Locking LugsStep 1. Determine the desired location of the appliance. Che
13Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Figure 5.5When installing in a rear vent configuration with no vertical rise: a Snorkel Kit must
14 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Step 5. Place the wall thimble cover over the pipe assembly and slide the appliance and vent as
15Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to
16 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up
17Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Ceiling FirestopNailsMinimum 1 in. (25mm) ClearanceMinimum 1 in. (25mm) ClearanceMinimum 1 in. (
18 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/112. Cathedral CeilingLevelCathedral Ceiling Support Box2 in. (51mm) Min. belowfinished ceilingCut
19Quadra-Fire • Topaz • 7009-113 Rev. i • 6/113. Class A Metal ChimneyFigure 5.20 High Wind Termination CapSheet Metal ScrewsDrill Four 1/8 i
2Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11and Welcome to the Quadra-Fire Family!Hearth & Home Technologies welcomes you to our tradition
20 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/114. Existing Masonry ChimneyType A - Up & Out Installations for Top Vent Configurations
21Quadra-Fire • Topaz • 7009-113 Rev. i • 6/1110 in. x 10 in. (254mm x 254mm) framed opening in wallStudwallMasonry ChimneyRetro Connector(4)
22 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11High Wind Termination CapTop Adaptor(3) Sheet Metal ScrewsFlashingStep 9.Attach the flex to the
23Quadra-Fire • Topaz • 7009-113 Rev. i • 6/116Gas InformationA. Fuel ConversionsBefore making gas connections ensure that the appliance bein
24 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11A B C Mounting ScrewsPressure Regulator TowerDiaphragmFigure 6.8 Turn control knob to the OFF
25Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Fire Risk.Explosion Risk.• If the information in these instructions is not followed exactly, a
26 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11• A small amount of air will be in the gas supply lines. When fi rst lighting appliance it will t
27Quadra-Fire • Topaz • 7009-113 Rev. i • 6/117Electrical InformationA. Recommendation for WireC. Standing Pilot Ignition System WiringSee B
28 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Figure 7.1CAUTIONLabel all wires prior to disconnection when servicing controls. Wiring errors c
29Quadra-Fire • Topaz • 7009-113 Rev. i • 6/118Appliance SetupA. Remove Shipping MaterialsRemove shipping materials from inside or underneath
3- TABLE OF CONTENTS -Section 1: Listing and Code Approvals A. Appliance Certifi cations ...4 B. Glass Specifi cations ...
30 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11D. AccessoriesInstall approved accessories per instructions included with accessories. Refer t
31Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11E. Front InstallationFronts shipped attached to faceFigure 8.12 To remove the face, loosen th
32 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11NOTE: Side brick panels will fit only if installed at an angle. Do not attempt to push the brick
33Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Figure 8.20 Insert locator pin into right front log. Insert rear log onto log pan over stud.
34 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11NOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct temper
35Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Figure 8.31 Blower Wiring DiagramFan Speed ControlThermal Disc(110 VAC)Power CordBLACK B
36 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11See Vent Graph for Recommendations on page 11 before you begin your adjustment. If your install
37Quadra-Fire • Topaz • 7009-113 Rev. i • 6/119Operating InstructionsA. Before Lighting ApplianceRead this entire manual prior to using the a
38 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11C. Lighting Appliance1. Set the thermostat to lowest setting. 2. Turn off all electric power
39Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11D. After Appliance is LitWhen you light your appliance, you may notice that it pro-duces heat w
4 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/111Listing and Code ApprovalsThe product is listed to ANSI standards for “Vented Gas Appliance Heat
40 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/1110TroubleshootingWith proper installation, operation, and maintenance your gas appliance will pr
41Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Symptom Possible Cause Corrective Action3. (Continued) c. Defective valve. Turn the valve knob
42 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/1111Maintaining and Servicing Your ApplianceAlthough the frequency of your appliance servicing and
43Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Inspect Maintenance TasksDoors 1. Inspect for scratches, dents or other damage and repair as ne
44 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/1112Reference MaterialsA. Appliance Dimension DiagramDimensions are actual appliance dimensions. U
45Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11B. Vent Components DiagramFigure 12.2 SL-D Series Vent Components4 in. (102 mm) inner pipe 6-
46 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11C. Vent Components List DescriptionHHT SLP M= Multi Pack (6)SimpsonDura-VentDirectVent Pro 4” P
47Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11C. Vent Components List (continued)* Stove Adaptor Kit (Vertical Cap Kit) Includes 30’-4” À ex,
48 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11D. Service Parts ListR TOPAZDirect Vent Gas StovePart number list on foll
49Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11 TOPAZIMPORTANT: THIS IS DATED INFORMATION. When requesting service or repl
5Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11NOTE: The following requirements reference various Massachusetts and national codes not contained
50 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11 TOPAZD. Service Parts ListIMPORTANT: THIS IS DATED INFORMATION. When requ
51Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11 TOPAZD. Service Parts ListIMPORTANT: THIS IS DATED INFORMATION. When requ
52 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11 TOPAZIMPORTANT: THIS IS DATED INFORMATION. When requesting service or repl
53Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appl
54 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11E. Limited Lifetime Warranty4021-645C 12-29-10 Page 1 of 2Hearth & Home Technologies Inc.L
55Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11E. Limited Lifetime Warranty (continued)4021-645C 12-29-10 Page 2 of 2WARRANTY CONDITIONS: 7
56DEALERSHIP WHERE PURCHASED:_________________________________________________________________________________________________________________________
6 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/112Getting StartedCheck building codes prior to installation.• Installation MUST comply with local
7Quadra-Fire • Topaz • 7009-113 Rev. i • 6/113Appliance Location and ClearancesA. Selecting Appliance LocationNOTE: · Illustrations refl ect t
8 Quadra-Fire • Topaz • 7009-113 Rev. i • 6/114Termination LocationsA. Vent Termination Minimum ClearancesFigure 4.2 Multiple Vertical Termin
9Quadra-Fire • Topaz • 7009-113 Rev. i • 6/11Figure 4.4 V= VENT TERMINALX= AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDA = 12 inc