1 7044-225 November 6, 20133100-I ACC WOOD INSERTAutomatic Combustion Control (ACC)Model(
10 7044-225 November 6, 201331-I ACCFigure 10.1Recommended LocationMarginalLocationLocati
November 6, 2013 7044-225 1131-I ACC3 ft. (91cm)MinimumLess than 10 ft. (305cm)2 ft. (61cm)3 ft.
12 7044-225 November 6, 201331-I ACC4 Chimney SystemsD. Masonry Chimney •Mustmeetmin
November 6, 2013 7044-225 1331-I ACCUL 1777 Insulated Stainless Steel Liner or Other Approved Lin
14 7044-225 November 6, 201331-I ACCF. Prefabricated Metal ChimneyFigure 14 .1E. Metal
November 6, 2013 7044-225 1531-I ACCInches MillimetersMinimumWidthofCavityOpening-Front 29-
16 7044-225 November 6, 201331-I ACCOvalizing round stainless steel liners to accom
November 6, 2013 7044-225 1731-I ACCFigure 17.1Outside Air Cover Plate (Discard)Rectangular Outsi
18 7044-225 November 6, 201331-I ACCB. Disassemble Firebox and Outer CanFor easier el
November 6, 2013 7044-225 1931-I ACCFigure 19.2Figure 19.3Figure 19.4Cast Iron Flue Located on Ap
2 7044-225 November 6, 201331-I ACC1 Important Safety InformationA.InsertCertication
20 7044-225 November 6, 201331-I ACCCorner BracketsFigure 20.5Figure 20.4Secure 2 Side Su
November 6, 2013 7044-225 2131-I ACCRemove 2 screws from both sides. Adjust the legs up or down
22 7044-225 November 6, 201331-I ACCJ. Snap Disc and Side Panel Installation1. Place sn
November 6, 2013 7044-225 2331-I ACCStrain ReliefGreen Ground Wire & NutDisconnect wires from
24 7044-225 November 6, 201331-I ACCDOUBLE-SIDED TAPEDOUBLE-SIDED TAPESCREWS ARE CIRCLEDE
November 6, 2013 7044-225 2531-I ACCFigure 25.1 Spark Arestor Cap Roof Flashing Storm Collar Joi
26 7044-225 November 6, 201331-I ACCService PartsR31I-ACCBeginning Manufacturing Date: Au
November 6, 2013 7044-225 2731-I ACC
28 7044-225 November 6, 2013Hearth & Home Technologies1445 North HighwayColville, WA
November 6, 2013 7044-225 331-I ACCModel:3100-I (ACC) InsertLaboratory: OMNITestLaboratories,I
4 7044-225 November 6, 201331-I ACCInstall Guide2 Getting StartedA. Design and Installati
November 6, 2013 7044-225 531-I ACCC. Negative PressureNegative pressure results from the imbala
6 7044-225 November 6, 201331-I ACCATTENTION INSTALLER:Follow this Standard Work Checklis
November 6, 2013 7044-225 731-I ACCFigure 7.1 Top View Figure 7.2 Front ViewFigure 7.3 - Side
8 7044-225 November 6, 201331-I ACCNOTE: Clearances may only be reduced by means approve
November 6, 2013 7044-225 931-I ACCC. Calculating Alternate Floor ProtectionMaterial Thermal Con