Page view 0
R
www.quadrafi
re.com
7050-128B
September 3, 2009
SANTA FE PELLET STOVE
Owner
s Manual
Installation and Operation
SANTAFE-MBK
Model:
W
ARNING
Please read this entire manual
before installation and use of this
pellet fuel-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
Do not overfi re - If any external part starts to
glow, you are overfi ring. Reduce feed rate.
Overfi ring will void your warranty.
Comply with all minimum clearances to com-
bustibles as specifi ed. Failure to comply may
cause house re.
Check building codes prior to installation.
Installation MUST comply with local, regional, state
and national codes and regulations.
Consult local building, re of c ials or authorities having
jurisdiction about restrictions, installation inspection,
and permits.
CAUTION
Tes ted and approved for wood pellets and shelled
e ld corn fuel only. Burning of any other type of fuel
voids your warranty.
CAUTION
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating and
maintenance instruc-
tions included.
Leave this manual with
party responsible for use
and operation.
Read, understand and
follow these instruc-
tions for safe installa-
tion and operation.
DO NOT
DISCARD
WARNING
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as replace.
A lert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl a mmable materials.
Keep clothing, furniture, draperies and other
a mmable materials away.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - SANTA FE PELLET STOVE

Rwww.quadrafi re.com7050-128BSeptember 3, 2009SANTA FE PELLET STOVEOwner’s ManualInstallation and OperationSANTAFE-MBKModel: WARNINGPlease read thi

Page 2 - ATTENTION:

Page 107050-128BSeptember 3, 2009Santa Fe Pellet Stove R*L Exception for Horizontal Installations:USA INSTALLATIONS: The non-combustible fl oor protec

Page 3 - TABLE OF CONTENTS

RSeptember 3, 20097050-128BPage 11Santa Fe Pellet Stove Do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic,

Page 4 - Listing and Code Approvals

Page 127050-128BSeptember 3, 2009Santa Fe Pellet Stove RImproper installation, adjustment, alteration, service or maintenance can cause injury or pro

Page 5 - Getting Started

RSeptember 3, 20097050-128BPage 13Santa Fe Pellet Stove 5Venting SystemsNOTE:• Illustrations refl ect typical installations and are FOR DESIGN PURPOSE

Page 6

Page 147050-128BSeptember 3, 2009Santa Fe Pellet Stove RB. Through The WallHorizontal termination cap must be a minimum of 12 inches. (305mm) from t

Page 7

RSeptember 3, 20097050-128BPage 15Santa Fe Pellet Stove We recommend a minimum of 60 inches (1.5m) vertical, however above the eave is preferred

Page 8 - Dimensions and Clearances

Page 167050-128BSeptember 3, 2009Santa Fe Pellet Stove RFire RiskInspection of Chimney:• Masonry chimney must be in good condition.• Meets minimum s

Page 9 - WA R NING

RSeptember 3, 20097050-128BPage 17Santa Fe Pellet Stove 6Mobile Home1. An outside air inlet must be provided for the combustion air and must remain

Page 10 - Santa Fe Pellet Stove

Page 187050-128BSeptember 3, 2009Santa Fe Pellet Stove R7Appliance Set-UpA. Outside Air Kit Instructions Flex HoseHose ClampCollar AssemblyTrim RingT

Page 11 - Vent Information

RSeptember 3, 20097050-128BPage 19Santa Fe Pellet Stove 3 to 3 inch Top Vent Adapter 3 to 6 inch Top Vent Offset Adapter 1. Put a layer of high te

Page 12 - C. Equivalent Feet of Pipe

Page 27050-128BSeptember 3, 2009Santa Fe Pellet Stove RHearth & Home Technologies welcomes you to our tradition of excellence! In choosing

Page 13 - Venting Systems

Page 207050-128BSeptember 3, 2009Santa Fe Pellet Stove RD. Optional Log Set Placement InstructionsFigure 20.14 PIECE LOG SET INSTALLATIONOPTIONAL TO

Page 14 - 45 Degree

RSeptember 3, 20097050-128BPage 21Santa Fe Pellet Stove E. Optional Gold or Nickel Grille & Trim RingFigure 21.1Heat Exchanger RodsGrille Bracke

Page 15 - Air Clearance to Pipe:

Page 227050-128BSeptember 3, 2009Santa Fe Pellet Stove R1. A 12 volt AC thermostat is required to operate this pellet appliance. You may use the in

Page 16 - Page 16

RSeptember 3, 20097050-128BPage 23Santa Fe Pellet Stove 8Operating InstructionsA. Fuel Size, Material and Storage1. Wood PelletsFuel pellets are mad

Page 17

Page 247050-128BSeptember 3, 2009Santa Fe Pellet Stove RFigure 24.2C. Before Your First Fire1. First, make sure your appliance has been prope

Page 18 - Appliance Set-Up

RSeptember 3, 20097050-128BPage 25Santa Fe Pellet Stove E. Fire CharacteristicsA properly adjusted fi re with the heat output control switch set on “

Page 19 - 3 to 6 inch Top V

Page 267050-128BSeptember 3, 2009Santa Fe Pellet Stove RH. Frequently Asked Questions Odors and vapors released during initial operation.• Curing of

Page 20 - Thermocouple

RSeptember 3, 20097050-128BPage 27Santa Fe Pellet Stove 9TroubleshootingWith proper installation, operation, and maintenance your appliance will prov

Page 21 - Heat Exchanger

Page 287050-128BSeptember 3, 2009Santa Fe Pellet Stove RSymptom Possible Cause Corrective ActionSlow or smoky start-up (Cont’d)Dirty exhaust and/or v

Page 22 - F. Thermostat Installation

RSeptember 3, 20097050-128BPage 29Santa Fe Pellet Stove Symptoms Possible Cause Corrective ActionConvection blower fails to start.#1 snap disc defect

Page 23 - Operating Instructions

RSeptember 3, 20097050-128BPage 3Santa Fe Pellet Stove Section 1: Listing and Code Approvals A. Appliance Certifi cations . . . . . . .. . . . . .

Page 24 - D. Starting Your First Fire

Page 307050-128BSeptember 3, 2009Santa Fe Pellet Stove R10Maintaining & Servicing Your ApplianceC. General Maintenance1. Types of Fuel Dependin

Page 25 - G. Iginition Cycles

RSeptember 3, 20097050-128BPage 31Santa Fe Pellet Stove WARNING• The cleaning slide plates must be fully CLOSED when appliance is operating. Hot p

Page 26 - ISSUES SOLUTIONS

Page 327050-128BSeptember 3, 2009Santa Fe Pellet Stove RFigure 32.2Vacuum insideExhaust VentingThe amount of ash buildup in the fi repot will

Page 27 - Troubleshooting

RSeptember 3, 20097050-128BPage 33Santa Fe Pellet Stove 11. Cleaning the Glass• Frequency: When clear view of the fi repot becomes obscure•

Page 28

Page 347050-128BSeptember 3, 2009Santa Fe Pellet Stove RB. High Ash Fuel Content Maintenance• Frequency: As needed• By: HomeownerCorrect Flame Size

Page 29

RSeptember 3, 20097050-128BPage 35Santa Fe Pellet Stove 1. Convection Blower Replacementa. Turn down the thermostat, let appliance completely cool a

Page 30 - A. Proper Shutdown Procedure

Page 367050-128BSeptember 3, 2009Santa Fe Pellet Stove RNOTE: Combustion Blower Gasket is also required. Sold separately under Part Number 240-0812

Page 31

RSeptember 3, 20097050-128BPage 37Santa Fe Pellet Stove D. Igniter Replacement 1. Shut down the appliance by turning down the thermostat and let the

Page 32

Page 387050-128BSeptember 3, 2009Santa Fe Pellet Stove RF. Baffl e & Brick ReplacementRight Brick InstalledBrick is flush against back wallBrick

Page 33

RSeptember 3, 20097050-128BPage 39Santa Fe Pellet Stove G. Glass Replacement• Glass is 5mm thick high temperature heat-resistant ceramic glass.• DO

Page 34 - WARNING

Page 47050-128BSeptember 3, 2009Santa Fe Pellet Stove R1Listing and Code ApprovalsA. Appliance Certifi cationC. Glass Specifi cationsE. BTU & Ef

Page 35 - Slots at Top and Bottom

Page 407050-128BSeptember 3, 2009Santa Fe Pellet Stove R11Reference Materials7. Heat ExchangersThe heat exchangers transfer hot air from the exhaust

Page 36

RSeptember 3, 20097050-128BPage 41Santa Fe Pellet Stove 16. ThermostatThe appliance is designed to run on a 12 volt AC thermostat. The heat antici

Page 37 - D. Igniter Replacement

Page 427050-128BSeptember 3, 2009Santa Fe Pellet Stove RB. Component LocationsRed Call LightFuseControlBoxVacuumSwitchJunction BoxHighMedLowHeat Outp

Page 38 - e & Brick Replacement

RSeptember 3, 20097050-128BPage 43Santa Fe Pellet Stove C. Exploded DrawingAssembly123456789101214192021232217181242627252829303132333435363713111516

Page 39 - G. Glass Replacement

Page 447050-128BSeptember 3, 2009Santa Fe Pellet Stove RD. Service Parts & AccessoriesTo order the entire assembly, order the top line part numb

Page 40 - Reference Materials

RSeptember 3, 20097050-128BPage 45Santa Fe Pellet Stove To order the entire assembly, order the top line part number only.To order an individual part

Page 41

Page 467050-128BSeptember 3, 2009Santa Fe Pellet Stove RTo order the entire assembly, order the top line part number only.To order an individual part

Page 42 - 10 Heat Exchanger Tubes

RSeptember 3, 20097050-128BPage 47Santa Fe Pellet Stove To order the entire assembly, order the top line part number only.To order an individual part

Page 43 - 7025-014 6-2-09

Page 487050-128BSeptember 3, 2009Santa Fe Pellet Stove RDate of Service Performed By Description of ServiceE. Service And Maintenance Log

Page 44

RSeptember 3, 20097050-128BPage 49Santa Fe Pellet Stove Date of Service Performed By Description of ServiceE. Service And Maintenance Log (Cont’d)

Page 45

RSeptember 3, 20097050-128BPage 5Santa Fe Pellet Stove 2Getting StartedA. Design, Installation & Location Consider-ationsWarning! Risk of Fire Da

Page 46

Page 507050-128BSeptember 3, 2009Santa Fe Pellet Stove RF. Warranty Policy

Page 47

RSeptember 3, 20097050-128BPage 51Santa Fe Pellet Stove

Page 48

RHearth & Home Technologies1445 North HighwayColville, WA 99114Division of HNI INDUSTRIES7050-128B September 3, 2009Page 52CONTACT INFORMATION:P

Page 49

Page 67050-128BSeptember 3, 2009Santa Fe Pellet Stove RC. Thermostat LocationThe thermostat’s location will have some effect on the appliance’

Page 50

RSeptember 3, 20097050-128BPage 7Santa Fe Pellet Stove H. Inspect Appliance & Components and Pre-Use Check ListReciprocating SawChannel LocksHamm

Page 51

Page 87050-128BSeptember 3, 2009Santa Fe Pellet Stove R3Dimensions and ClearancesA. Appliance DimensionsFigure 8.2- Front ViewFigure 8.1 - Top View

Page 52 - FE PELLET STOVE

RSeptember 3, 20097050-128BPage 9Santa Fe Pellet Stove Straight Back Against WallInches MillimetersABack Wall to Appliance 2 51BSide Wall to Applian