Also, listed prefabricated metal thimbles can be bought for use with wood stoves. The manufacturer's installation instructions lor
a thimble must be strictly followed to assure the safety of the system. Be sure to maintain the designated clearance to combustible
materials.
1.
Brick chimney thimbleassembly
--
Construction of a brick thimble assembly requires 12 in. of brick around afire clay liner.
Be sure the point of penetration allows a
24
in. clearance from the top of the connector to the ceiling. An opening of
30
in. (for
a
6
in. chimney connector) must be cut in the wall to maintain the required 12 in. of brick separation from combustibles. It will
be necessary to cut wall studs and install a header and sill frame to maintain the proper dimensions and to hold the weight of
the brick.
Wood Stud
2
lnches Clearance
.From Chimney Wall
Header
1!11
16
Thimble
ASS^^^^\^.
1
2
Inches
of
Brick
Separation From Clay
Fireclay Liner
518"
~inimum
'
or Eauivalent
Wall
Minimum 3-112 in.
(4
in. nominal) thick solid bricks are to be used. The fire clay liner (ASTM C35 or equivalent) minimum 518 in
wall thickness, must not penetrate into the chimney beyond the inner surface of thechimney flue liner and must be firmly cemented in
place. if it is necessary to cut a hole in the chimney liner, useextreme care to keep it from shattering. Refractory mortar must be used
at the junction to the chimney liner. After the assembly is complete, insert the chimney connector in the fire clay liner. Do not push it
beyond the inside edge of the chimney liner because this will affect the draw of the chimney.